Hi

Yeah i think you are right since i saw a warning in the output saying the atoms are too close. Ok now for example if my input is one unit cell of FCC i understand what must be my lattice vectors. I use here 2*2*2 cells. So can i not use the lattice vectors of the same unit cell? Should I scale the lattice vectors by the same value? I'm really sorry and this is first time I'm doing this stuff and so I'm confused

Regards
Ram

On 02/28/2011 04:08 AM, Henrik Löfås wrote:
Hi,

This has nothing to do with the K-point sampling, but your definition of the unit cell/coordinates are completely off. Your unit cell is too small, hence all the atoms are placed very close. Please, use a program to visualize your input structure to check that it looks ok before doing any calculation.

Best Regards
Henrik

2011/2/28 janakiraman balachandran <[email protected] <mailto:[email protected]>>

    Hi All

    I'm trying to run a SCF calculation for a 2*2*2 Au cluster. I'm
    having issues with K point sampling. I do not understand what
    value of kgrid_Monkhorst_Pack and kgrid_cutoff i need to use. Is
    there a simple thumb rule using reciprocal vectors that i can use
    to specify these details. My scf is not converging even after 100
    cycles. But these cycles also are very fast. the total calculation
    happened in 30 mins. It would be great if someone can help. I have
    attached a copy of my fdf file along with the email. It would be
    of real great help if some one can help me in this issue

    Regards
    Ram



Responder a