You should test convergence of your results by using larger grids.  This has
been discussed on the forum many times.  If your system (e.g. energy) has
converged with a 1x1x1 sampling, then you should get the same results with a
1x1x4.  You will need to experiment, until you get the level of accuracy
with respect to computation time you require.

Chris

On 13 April 2011 00:34, deepak srinivasan <[email protected]> wrote:

>
> Hi
> Thanks for pointing out my mistake. I forgot to add Lattice Vectors to my
> input file.
> I have another doubt
> I am trying to simulate a molecule(AGNR), and somewhere i read that  k-grid
> of 1 x 1 x 1 will suffice for molecules.
> However i am trying to use 1 x 1 x 4 grid. Will it change the result by
> much as it tends to take a lot of time when compared to 1 x 1 x 1 grid.
> Which one would be the bset to use
>
> Also i am using a shifted molecule (it has no zero coordinates) and forcing
> unshift into it by putting lambda points as 0.0 in k grid Monkhorst Pack.
> Will it cause problems
>
> Sorry if my questions sound dumb
>
>
>
> --
> regards
> deepak
> 3rd Year Under Graduate
> Electronics Design and Manufacturing
> IIIT (D&M),Kancheepuram
> IIT Madras Campus,Chennai
>

Responder a