Actually both, Hartree and Rydberg, are atomic units of energy and basically 
just depends  if you are  studying physics or chemistry. I don't understand the 
problem with this issue, and indeed the systemlabel.bands file is in eV.

Best Regards,
Eduardo.

----------------------------------------
Miguel Eduardo Cifuentes Quintal
PhD Student
Department of Applied Physics
Cinvestav-Merida, Mexico.

e-mail: [email protected]
----------------------------------------

> Date: Sat, 25 Jun 2011 17:39:22 +0800
> From: [email protected]
> To: [email protected]; [email protected]
> Subject: Re: [SIESTA-L] How to interprete x-axis in bands-file?
> 
> On 06/24/2011 06:32 PM, Hongyi Zhao wrote:
> > On 06/24/2011 01:03 PM, Miguel Eduardo Cifuentes Quintal wrote:
> >>
> >> Well, if I'm right, the internal units of siesta and others DFT-codes
> >> are the atomics ones, but for this specific case you can take a look at
> >> the bands.F file in the source directory of the siesta code, and confirm
> >> this by yourself.
> >
> > Thanks a lot, I can find the following things in bands.F:
> >
> > ----------------
> > C *************************** UNITS ***********************************
> > C Lengths in atomic units (Bohr).
> > C k vectors in reciprocal atomic units.
> > C Energies in Rydbergs.
> 
> The energy's atomic unit is Hartree, not  Rydberg,  according to your 
> above description,  I cann't understand why use the Rydberg as energy's 
> unit in bands.F.  Any hints?
> 
> > C ***************** BEHAVIOUR *****************************************
> > ----------------
> 
> Regards.
> -- 
> Hongyi Zhao <[email protected]>
> Institute of Semiconductors, Chinese Academy of Sciences
> GnuPG DSA: 0xD108493
                                          

Responder a