Hi, Roberto

“ No, COOP/COHP do not depend on d1, d2. Those numbers just specify
 search radii for your target atoms.”
>> what's search radii here? Only if it's properly chosen then the program
      will work. What if it's not properly chosen, will the generated COOP
      curve be incorrect?

Best Regards,.
Bing

2012/9/13 R.C.Pasianot <[email protected]>

>
>  Hi Bing Huang,
>
>  ...
>>
>> Do the number '1' and '3' below just stand for the
>> tag number of atoms I'm interested in?
>> ...
>>
>
>  Yes
>
>  ------------------------------**------------------------------**-----
>>
>>       1
>>       d1  d2   (distance range bracketing atom #3)
>>       3
>> ------------------------------**------------------------------**-----
>>
>> Apparently COOP/COHP curves depends strongly
>> on d1&d2, so I wonder how to choose d1&d2, is
>> ...
>>
>
>  No, COOP/COHP do not depend on d1, d2. Those numbers just specify
>  search radii for your target atoms. Thus any properly chosen pair
>  will do. Sensitive parameters are the number of (energy) points
>  and smearing (-n and -s, if I remember correctly, check mprop help).
>
>  Best,
>
>  Roberto
>
>
>

Responder a