Dear Nick,

I have tried it in TranSIESTA. If TranSIESTA does not find a *TSDE or *DM, then 
it will use SIESTA method to generate a *.DM despite of the exist of a 
Rho.IN.grid.nc file. That is what I have experienced in trunk-444. So, I think 
TranSIESTA does not have this feathure.

With best regards.

Guangping Zhang

2013-12-09






发件人:Nick Papior Andersen <[email protected]>
发送时间:2013-12-09 08:50
主题:Re: [SIESTA-L] Is it possible for TranSIESTA to use a Rho.IN.grid.nc or 
DeltaRho.IN.grid.nc file to initialize the SCF?
收件人:"[email protected]"<[email protected]>
抄送:

I have never used it myself, but from looking at the code it does seem like it 
should be possible. Why do you know it is not available in TranSIESTA?



Kind regards Nick



2013/12/6 zgp121 <[email protected]>

Dear TranSIESTA developers:

In SIESTA, one can use SCF.Read.Charge.NetCDF or 
SCF.Read.Deformation.Charge.NetCDF options to use the Rho.IN.grid.nc or 
DeltaRho.IN.grid.nc file to initialize the SCF. This is very important for 
increasing the basis size for the same systems. However, it is not available in 
TranSIESTA.

I am wondering is it possible in TranSIESTA?


With best regards.

Guangping

2013-12-06

Responder a