Why is that strange?
The TSDE file does not exist, hence it starts diagon to calculate an
initial guess for the Hamiltonian.


2015-04-22 8:07 GMT+02:00 邵德喜 <[email protected]>:

> Dear everyone,
> I’m sorry to disturb but something strange appears in the beginning of the
> OUTPUT file just as follows:
>
>
> siesta:                 ==============================
>                             Begin CG move =      0
>                         ==============================
>
> outcell: Unit cell vectors (Ang):
>        41.000000    0.000000    0.000000
>         0.000000   32.000000    0.000000
>         0.000000    0.000000   53.992152
>
> outcell: Cell vector modules (Ang)   :   41.000000   32.000000   53.992152
> outcell: Cell angles (23,13,12) (deg):     90.0000     90.0000     90.0000
> outcell: Cell volume (Ang**3)        :  70837.7037
> New_DM. Step:     1
> Initializing Density Matrix...
> TRANSIESTA: No TS-DensityMatrix file found
> TRANSIESTA: Initialization runs using diagon
>
> And in the end, the job is failed after a while.
>
>


-- 
Kind regards Nick

Responder a