Hi all,
I have problems with the trunk-424 version: I think it is the the new grid
balancing system. It works for a few SCF cycles and then crashes.
The unit cell is 26x26x50 Ang, 1000 atoms.
Is my system too large? It crashes on anything from 64 to 512 CPUs.
I don't think updating to the latest version would help since load
balancing was untouched there.
Alex.
-------------------------------------------------------------
InitMesh: MESH = 288 x 288 x 540 = 44789760
InitMesh: (bp) = 144 x 144 x 270 = 5598720
InitMesh: Mesh cutoff (required, used) = 300.000 316.798 Ry
ExtMesh (bp) on 0 = 244 x 118 x 134 = 3858128
New grid distribution: 2
1 71: 108 38: 74 199: 235
2 1: 36 1: 37 30: 198
...
63 1: 37 110: 144 199: 237
64 1: 36 111: 144 238: 270
New grid distribution: 3
1 37: 72 73: 108 181: 225
2 37: 72 1: 36 181: 225
...
63 73: 108 37: 72 181: 225
64 1: 36 109: 144 226: 270
APPLICATION TERMINATED WITH THE EXIT STRING: Hangup (signal 1)