Hi,

It is not an error, nor a bug in the code. It is just an informational message 
that is printed whenever you are running
a calculation without k-point sampling for a system whose unit cell is not 
large enough to allow the representation of all orbital interactions (matrix 
elements of H and S) univocally. This is no problem for a gamma-point 
calculation, since no phases are needed and matrix elements for different 
images can simply be added. But the small cell might mean that k-point sampling 
might make a difference for this system. Also, some analysis tools (those for 
computation of COOP/COHP curves, for example), will not work properly if the 
matrix elements of S and H have been "folded". In this case you can use the 
'ForceAuxCell' option (see the manual).

 Alberto


----- El 27 de Feb de 2019, a las 04:15, Mina Sedighi [email protected] 
escribió:

| Dear Siesta users and developers,
| 
| 
| Thank you for all of your advice. I am using Siesta version 4.1-b3 on Compute
| Canada (graham) cluster. I faced the following error at the first of my CG
| simulation:
| 
| 
| Folding of H and S is implicitly performed
| 
| 
| As I read in the archive of mailing list, it is a bug of the code. Could you
| please guide me how I can fix it? Thank you so much in advance.
| 
| 
| Best regards,
| 
| Mina

Responder a