Hello everyone,

I just started running SIESTA, and I am a complete beginner. As a test case, I 
decided to run simple single point calculation for lead using GGA-PBE. Here is 
the input script I was using:

#General system specifications
SystemName          Pb1
SystemLabel         Pb1
NumberOfAtoms       1
NumberOfSpecies     1

# Species index, atomic number, species label
%block ChemicalSpeciesLabel
1   82   Pb   /scratch/ddangic/nc-sr-05_pbe_standard_psml//Pb.psml
%endblock ChemicalSpeciesLabel

#Atomic coordinates
AtomicCoordinatesFormat  Fractional
%block AtomicCoordinatesAndAtomicSpecies
0.000000000000    0.000000000000    0.000000000000    1
%endblock AtomicCoordinatesAndAtomicSpecies

#Unit cell for the calculation
LatticeConstant 1 Ang
%block LatticeVectors
-0.000000000000    2.534635481000    2.534635481000
2.534635481000    0.000000000000    2.534635481000
2.534635481000    2.534635481000    0.000000000000
%endblock LatticeVectors

%block kgrid_Monkhorst_Pack
8    0    0    0.0
0    8    0    0.0
0    0    8    0.0
%endblock kgrid_Monkhorst_Pack

#Real space grid
MeshCutoff 300.0 Ry

# Convergence of SCF
SCF.Mixer.History 5
SCF.H.Tolerance 1.0e-6 eV
SCF.EDM.Tolerance 1.0e-6 eV

# Basis set definition
PAO.BasisSize   DZP
PAO.EnergyShift 2.000000e-03 Ry

XC.functional GGA
XC.authors    PBE

The pseudopotential is downloaded from the PseudoDojo website. I tried 
different value for k-point mesh (8^3 to 30^3), MeshCutoff (50 - 325 Ry) and 
PAO.EnergyShift (0.002 to 0.024 Ry) and I am consistently getting pressure to 
be around 450 GPa. This is unexpected since the lattice constant (as I 
understand SIESTA input) should be already close to the experimental one. Am I 
doing something obviously wrong? What could be the issue?

Kind regards,

Đorđe
-- 
SIESTA is supported by the Spanish Research Agency (AEI) and by the European 
H2020 MaX Centre of Excellence (http://www.max-centre.eu/)