On Friday, April 25, 2014 at 06:03:47 PM, Marek Vasut wrote: > Init the cur_sample_rate to 200kHz. This is now the default sample > rate for the ASIX Sigma if no other is specified by -c samplerate=N > on the command line. Without this change, the driver would crash on > SIGFPE because a division by zero would happen. > > Signed-off-by: Marek Vasut <[email protected]>
This should fix the SigFPE problem, please apply on top of 0001 of this series. Still, the trigger logic seems completely bugged and the only sampling limit "mode" that works now is --time in sigrok-cli , the limiting by number of samples (--samples) will need thorough inspection. Best regards, Marek Vasut ------------------------------------------------------------------------------ Start Your Social Network Today - Download eXo Platform Build your Enterprise Intranet with eXo Platform Software Java Based Open Source Intranet - Social, Extensible, Cloud Ready Get Started Now And Turn Your Intranet Into A Collaboration Platform http://p.sf.net/sfu/ExoPlatform _______________________________________________ sigrok-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/sigrok-devel