Hello, I think I need some advice how data packets and multiple channels of a measurement should be related.
I would like to be able to output the data from several analog oscilloscope channels belonging to one 'frame' ( acquired for the same trigger event, to my understanding ) into separate columns of a CSV file. The hameg-hmo driver sends separate data packets for each channel. The csv output module ( not supporting analog yet ) immediately creates output when processing an incoming packet. Should rather the device driver generate a 'multi channel' package from the beginning, or should the output module buffer data until all channels are complete ? Or should the buffering even happen somewhere in between ? Regards, Mathias ------------------------------------------------------------------------------ Dive into the World of Parallel Programming! The Go Parallel Website, sponsored by Intel and developed in partnership with Slashdot Media, is your hub for all things parallel software development, from weekly thought leadership blogs to news, videos, case studies, tutorials and more. Take a look and join the conversation now. http://goparallel.sourceforge.net _______________________________________________ sigrok-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/sigrok-devel