Hi,

the patch is merged now, thanks a lot!

I could reproduce the issue indeed and the patch does fix it. I'm
getting correct readings on an AX device that I know is correctly
calibrated and it now does show the correct voltage readings with
libsigrok (corfirmed with a DMM, too).


Cheers, Uwe.
-- 
http://hermann-uwe.de | http://randomprojects.org | http://sigrok.org

------------------------------------------------------------------------------