For your reference, this is the correct (and updated) order to apply the pending libsigrok patches (from the first one that should be applied to the last one to apply):
1. Support earlier versions of udev in the udev rules 2. hameg-hmo: use the appropriate memory free function [bug #1324] 3. hameg-hmo: Remove an invalid product model and add a valid product model [bug #1322] 4. hameg-hmo: support all 16 instead of only 8 digital channels on HMO3XX2 5. Add support to configure the number of samples to acquire (hameg- hmo) (v5) 6. Correctly set the length of the binary acquisition data buffer (v2) [bug #1323] 7. Use appropriate default serial port options for USB connections [bug #1321] 8. Update the default serial port options for Rohde&Schwarz and Hameg devices (v2) [bug #1321] 9. Support predefined logic thresholds on Hameg/Rohde&Schwarz HMO driver (hameg-hmo) (v4) 10. Attempt to support the Rohde&Schwarz RTC1000 MSO (hameg-hmo) 11. Attempt to support the Hameg/Rohde&Schwarz HMO1202 MSO (hameg-hmo) 12. Update the SCPI command enumerations 13. hameg-hmo: Correctly set the trigger type [bug #1328] 14. hameg-hmo: Introduce the Pattern (Logic) Trigger functionality The total number of pending patches is 14 (fourteen). They are a mixture of bug fixes (1,2,3,6,7,8,13), functionality enhancement (4,5,6,9,14), new device support (3,8,10,11) and maintenance (12). Please note that following user feedback and developer review respectively, the following two patches have been dropped (they should be ignored and not merged, although they have no side-effects but just introduce unneeded complexity): - hameg-hmo: fall back to Probe Unit Setup command if Enquiry command fails - Support the official SCPI command specifications for single-POD devices (hameg-hmo) I hope this helps. Regards, Guido Trentalancia _______________________________________________ sigrok-devel mailing list sigrok-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sigrok-devel