For your reference, this is the correct (and updated) order to apply
the pending libsigrok patches (from the first one that should be
applied to the last one to apply):

1. Support earlier versions of udev in the udev rules
2. hameg-hmo: use the appropriate memory free function [bug #1324]
3. hameg-hmo: Remove an invalid product model and add a valid product
model [bug #1322]
4. hameg-hmo: support all 16 instead of only 8 digital channels on
HMO3XX2
5. Add support to configure the number of samples to acquire (hameg-
hmo) (v5)
6. Correctly set the length of the binary acquisition data buffer (v2)
[bug #1323]
7. Use appropriate default serial port options for USB connections [bug
#1321]
8. Update the default serial port options for Rohde&Schwarz and Hameg
devices (v2) [bug #1321]
9. Support predefined logic thresholds on Hameg/Rohde&Schwarz HMO
driver (hameg-hmo) (v4)
10. Attempt to support the Rohde&Schwarz RTC1000 MSO (hameg-hmo)
11. Attempt to support the Hameg/Rohde&Schwarz HMO1202 MSO (hameg-hmo)
12. Update the SCPI command enumerations
13. hameg-hmo: Correctly set the trigger type [bug #1328]
14. hameg-hmo: Introduce the Pattern (Logic) Trigger functionality

The total number of pending patches is 14 (fourteen). They are a
mixture of bug fixes (1,2,3,6,7,8,13), functionality enhancement
(4,5,6,9,14), new device support (3,8,10,11) and maintenance (12).

Please note that following user feedback and developer review
respectively, the following two patches have been dropped (they should
be ignored and not merged, although they have no side-effects but just
introduce unneeded complexity):

- hameg-hmo: fall back to Probe Unit Setup command if Enquiry command
fails
- Support the official SCPI command specifications for single-POD
devices (hameg-hmo)

I hope this helps.