@Uwe Hermann

Could you help, Please ?

I find same issue and fixed the bug for kingst-la2016 , could you please fixed it for logicstudio and rebuild it for win64 install package ?

https://github.com/sigrokproject/libsigrok/pull/112

Fix kingst-la2016 driver (for windows) #112

There are two fixes for bugs that inhibit the driver to operate with the Windows 10 USB driver.

1. When uploading the firmware, the correct configuration must be selected.
2. The*attribute*((*packed*)) is not accepted by the MXE compiler and
   an invalid transfer is sent to the USB device.
   Each fix is in a separate commit.

Best Regards
Andy Lu

Dear All,

I want using pulseview with my lecroy logicstudio16, i had install winusb drive and extera the bitstream file , it seem

no problem to connection ,but it will report capture failed when i clik start button. see the log as below :

sr: resource: Opened 'C:\Program Files\sigrok\PulseView\share\sigrok-firmware\lecroy-logicstudio16-16.bitstream'.

sr: session: Using thread-default main context.

sr: session: Starting.

sr: hwdriver: lecroy-logicstudio: Starting acquisition.

sr: session: bus: Received SR_DF_HEADER packet.

sr: usb: Failed to get libusb file descriptors.

sr: session: Could not start lecroy-logicstudio device usb/7-6 acquisition.

sr: hwdriver: lecroy-logicstudio: Stopping acquisition.

Notifying user of session error: "Capture failed" ; "generic/unspecified error"


Could you help ,please ?


Best Regards
Andy Lu
_______________________________________________
sigrok-devel mailing list
sigrok-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/sigrok-devel

Reply via email to