I had similar problems with my new Distiller,I double distill for best 
results.Also,I lowered the level of the water in the tank by about 1 cm.This 
prevents boiling expansion of H2O from spilling over into the condenser 
coil.When I  just want topical EIS,I distill once.But if I run short of good,I 
will take this one orally.not in large amounts though.

Harold
  ----- Original Message ----- 
  From: Asif Nathekar 
  To: [email protected] 
  Sent: Saturday, June 18, 2011 3:48 PM
  Subject: CS>home made CS generater


  Hi,

  i made a post three weeks ago, to which many kind people helped regarding 
building my CS generator.

  it was built using a LM317T chip to control current at 1.5ma to three anodes  
and three cathodes, total area squared of anodes is 3 inches (thin silver 
wires). And Voltage at 30v initially.

  I was getting large visible particles of silver coming of the electrodes, 
with the kind help of the people on Silver-list I was able to work on some 
possible causes namely.

  1:  Electrodes were too close, they were 3 cm apart, they are now 5 cm (2 
inches) apart.
  2 :  Water provided was some how contaminated, I bought my own water 
distiller and am able to eliminated that (0 ppt, 0 microseimens)
  3 : Paper towel was used to clean the cathode, now using green plastic 
scouring pads (no detergent)
  4 : Contaminated brewing vessel , I cleaned with no detergent, and rinsed 
with distilled water, distilled water in brewing vessel tested 0 microseimens.

  I have implemented these changes, however I am still getting similar results 
as before, meaning visible particles of silver, but massively reduced amount of 
crap at the bottom of the jar.

  when the electrodes are dipped into the freshly distilled water it conducts 
1.2ma immediately... which eventually gets to 1.5ma, and I have a voltage of 
30v across which when dipped into the fresh water measures 14v immediately (of 
course the voltage is being reduced to keep the current at 1.5ma).. Which means 
its conductive... but measures 0ppm, 0 microseimens!

  any suggestions?...

  p.s. when it gets to 8 volts it tests at 5 microseimens. so its doing 
something!.. 