Hi Ed & All,

So you have been making LVDC,  CS. Tell me is the T.E. visible in
ordinary room light?? If it is you are making any inferior product.

So why work with HVAC which makes an inferior product. I have tried it
and junked the transformer. It has a bight T.E. and has low PPM, and has
color problems.

The T. E. in my LVDC is not visible except in subdued light or in a dark
room. If you have checked  the web www.natural-immunogenics.com
and seen what most people are making, then maybe you should spend the
time investigating how to make CS that has the smallest particles.

MY, MY, how have I stirred the pot !!!!!!!

I don't need hot water, or seeding, I just use 26 vdc, with 7/16"
spacing of #14 silver wire with a wet length of 3-1/2" of wet length
with 14 oz of good DW in a 16 oz SOLO cup from the grocery store.  A
1-1/2v dc motor from Radio shack with three 10 ohm resistors in parallel
to slow the motor down. The stirred is a 2" length of plastic insulation
form a #14 wire. Pull the wire out about 1/4" and clip off the copper.
Place a 15 deg bend about 1/2" from the bottom of the wire, then slip in
on the motor shaft.

Make a plastic lid for the SOLO cup and glue the motor on to it. Make a
1/4" hole in the center for the motor shaft.  Make two holes about 7/16
to 1/2" apart, offset from the center by 1" and make the hole at right
angles to a radius.

You need two digital meters. one for monitoring the cell current and the
other for measuring the conductance. Measure both at 15 min. intervals.
and when the conductivity plot starts to bend to the right agglomeration
is setting in. That will cause a drop in PPM and conductivity, along
with increased particle size.

If you want proof ask me for a copy of the shareware program "Wplot" and
I will send it "off list" along with plots of many CS runs that will
show you what is happening and how  to make a very good CS.

I have just received my 8th box of 50 sets of test pillows for my
spectrophotometer, in the last three months I have use 4 boxes in
studying this
CS process.  If you wish to argue show me your data in plot form.

"OLE BOB"  :-(






--
The silver-list is a moderated forum for discussion of colloidal silver.

To join or quit silver-list or silver-digest send an e-mail message to: 
[email protected]  -or-  [email protected]
with the word subscribe or unsubscribe in the SUBJECT line.

To post, address your message to: [email protected]
Silver-list archive: http://escribe.com/health/thesilverlist/index.html
List maintainer: Mike Devour <[email protected]>