> > The next question is: How can I build in a fuse or
> > breaker to prevent any possibility of my clients (or
> > myself) getting electrocuted in case of accident?
> 
> I've never heard of a small AC-DC transformer shorting 120VAC to the
> output; they only die, to my knowledge...

Would it be too disruptive just to put a resistor in series with the 
output as a worst case current limit? Select the value such that it 
limits current to a non-lethal value at 120 volts, while only dropping 
a little voltage at the design output level.

Another easy alternative is to put a zener diode "crowbar" circuit on 
the output. This consists of a low current fuse in series with one or 
both of the supply output leads, and a zener diode connected between 
the + and - leads after the fuses.

This setup causes the fuse(s) to blow if the output voltage exceeds the
zener's reverse bias breakdown voltage, or if the polarity of the
supply should reverse, either of which will cause the zener to conduct.

Not perfect protection by any means, but cheap. It won't protect 
against getting a shock from the line to another object unless your 
body conducts enough to blow the fuses.

Some help from our electrical engineers would be good!

M.

[Mike Devour, Citizen, Patriot, Libertarian]
[[email protected]                        ]
[Speaking only for myself...               ]


--
The silver-list is a moderated forum for discussion of colloidal silver.

To join or quit silver-list or silver-digest send an e-mail message to: 
[email protected]  -or-  [email protected]
with the word subscribe or unsubscribe in the SUBJECT line.

To post, address your message to: [email protected]
Silver-list archive: http://escribe.com/health/thesilverlist/index.html
List maintainer: Mike Devour <[email protected]>