Hi Eis'ers, For those who have Wplot32, I will attach the data plot of my latest investigation.
For all others I will give a word picture for you. The anode is 5" high by 8" wide formed into an arc of 2" radius. The Cathode is a single rod 3/64" diameter x 7". A submerged pimp was run continually. On 5/24/03 I ran a two gallon brew using, 1 gallon of 1.29 Vcs @4.69 PPM, and 1 gallon of 18 Vcs @ 4.62 PPM. Initial conditions: I start = 2.64 ma. at 2 hrs. I(2) = 5.61 ma. and Ag+ = 5.94 PPM At 3 hours I(3) = 11.01 ma. and Ag+ = 8.58 PPM. System shutdown of 49 hours with CS in the covered tank. On restart I = 7.76 ma. After 50 minutes of brew the I(final) = 12.61 ma. That is were current limiting set in. Tested after 2 hour rest: Cf = 48.6 uS/cm; pH = 7.2; Ag+ = 39.6 PPM. That's right the last 50 minutes!!! Weak T.E. and crystal clear. "Ole Bob"
5x8 Anode repro.PLT
Description: application/unknown-content-type-plt_auto_file