Matthew McCann PE wrote:

> Rice University's electrical engineeringlaboratory has a good on-line
> report onamounts of hazardous electricity.(see website for lab course
> ELEC 241.)According to this, the threshold forventricular fibrillation
> is given inwatt-seconds, i.e. energy, not current.The threshold is
> 13.5 watt-seconds.
>
>
> There needs to be a time element associated with this as well.  That
> is, even a microamp at a millivolt, would produce this much energy
> over a long enough time. My guess is that is it for 60 hertz, which
> would be about 8 milliseconds. But even so that number seems very
> fishy. Lets say you are looking at one pulse of 60 hertz, which is
> 8.33 milliseconds.  If you have 10 volts the the amount of current to
> exceed this would be 162 AMPS!!!!  This would be far beyond deadly.
>

Marshall