According to various lab tests on commercial and home-made CS, most electrically made CS is in the 10 to 25 TOTAL ppm range. TOTAL ppm is the sum of the IONIC (or dissolved) silver (roughly measurable with a TDS or EC meter) and the PARTICLE (or colloidal) silver thats visible with a laser but not measurable with any meter.

The proportion of ionic to particle ppm is usually about 90% ionic to 10% particle give or take 5%.

But most of these tests have been done on nice clear CS because thats the stuff we are happy to drink and we can make it repeatedly without too much trouble.

(At around $700 for a full analysis with a particle size report its understandable that someone is only going to get a report on a product they can reliably reproduce)

But this seems to leave a gap in whats known about the actual maximum TOTAL ppm thats possible with, for example, a home brew system. If we ignore aspects such as color and light sensitivity, what TOTAL ppm can we really achieve?

The typical maximum IONIC ppm for a clear brew seems to be about 30. I understand theres a solubility limit involved here so its not something that can be played around with a whole lot. But can the particle PPM be raised by much?

I believe that once the ionic max is reached, the brew looses clarity and any additional dissolved ions immediately form compounds and either become increasingly large, or increasingly more abundant, colloids.

So my question is, whats the maximum colloidal PARTICLE ppm thats possible over and above the ionic ppm? Is there a physical limit for that too?

David