Greetings,
I made two gallons of EIS using the assymeterical electrodes using 33 volts
DC.
Brew time was 5.5 hours, Conductance on the next dasy was 18.3 uS/cm and the
Ag+ was 13.63 PPM.
I filled 3- 1.5 Diet Rite cola bottles. After 24 hours three of then had a
slight yellow color, which was probably due to incomplete hot water rinse. The
other is crystal clear.
I added one drop of 35% H2O2 to two of the bottles and the next day they were
sligtly gray. So I remove about ten ounces form each bottle into a 16 oz Solo
plastic cups.
Both of the bottles and cups were frozen sold and then removed from the
freezer to thaw.
The thawed product is crystal clear and the Ag+ is now 12.1 PPM and the
conductance is 12.9 uS/cm.
So when you get off-color EIS (not CS) then do the same.
"Ole Bob"