On Thursday, April 11, 2013 at 7:00 AM, Bob Supnik wrote: > 1. Four Massbus channels on the PDP-11 (or VAX). This is straightforward. > The RH simulator already supports two, and the extensions from two to four > use the existing mechanisms: > > - add the register blocks definitions to the header file > - define additional RHC, RHD devices with matching unit and register > definitions > - look for places where "2" is hardwired as the maximum number > - modify the autoconfiguration table for the additional device addresses
This is most of it, but additional devices and units must also be defined in the pdp11_rp and pdp11_tu which then need to be connected to the new RHC and RHD devices created above. Maybe a way to dynamically assign particular rp or tu devices to a particular Massbus is also be necessary (someone might want 3 disk controllers and 1 tape, while others might want 3 tape and 1 disk controller, etc.). If mixed configurations are possible something needs to validate that there are no Massbus conflicts. > 2. While real documentation for the RS03 and RS04 is lacking, they are > described in adequate detail in the early PDP-11 IO handbooks, which are on > BitSavers. This would probably suffice to run the operating systems, but not > diagnostics. There is also some information on issues in the RS03 and RS04 in > the Massbus standard. Good to know. This, along with the driver sources which Johnny Billquist mentioned are probably sufficient for someone to implement things. - Mark _______________________________________________ Simh mailing list [email protected] http://mailman.trailing-edge.com/mailman/listinfo/simh