As Mark mentioned recently I've already done quite a bit of work on a CI and DSSI simulation for the VAX. I originally started working on this quite a few years ago and I did have it mostly working at one point.
I've taken my latest development version and tried to tidy it up a bit and merge it into the latest Simh code. I haven't had chance to work on this properly for quite a while now so I'm just going to release what I've got as there seems to be quite a bit of interest. The result is in a branch on Github: https://github.com/9track/simh/tree/CI Unfortunately this latest version does not quite work. It seems that something got broken in one of the more recent updates. I might get some time later this week to debug it. I don't think it will be anything major. The other problem is that this was based on a much earlier release of Simh and the sim_sock module has changed beyond recognition. To allow people to be able to build this I've temporarily bundled the old sim_sock into the repo as ci_sock with some changed to add multicast sockets. To get the CI port to work you will need console media containing the microcode. The O/S will not attempt to initialise the port unless it finds these files. The actual microcode is not used by the simulation. For convenience I've uploaded some suitable console images here: http://www.9rack.net/simh/750console.zip http://www.9rack.net/simh/780console.zip http://www.9rack.net/simh/8600console.zip To setup the CI port use commands similar the the following: ; Enable the CI port sim> set ci en ; Set the port number (range 0-15). This would be set by jumpers on the real adapter sim> set ci node=4 ; Set the (unique) TCP port number for virtual circuits. Other simulators will use this port to establish virtual circuits to this node sim> set ci port=3818 ; Attach the CI port to a UDP multicast group. This will be used so that nodes can 'discover' each other prior to a virtual circuit being opened. This should be the same address and port on all nodes belonging to the same CI. The address should be in the range 239.0.0.x sim> att ci 239.0.0.37:3812 Feel free to ask any questions and I'll try to help where I can. The sources of information I used when developing this were: Chapter 5 of EY-9222E-SA-0001 - VAXcluster Maintenance Student Workbook Volume 1 EK-CI750-TD - CI750 Hardware Technical Description VMS source listings Ultrix source listings There are more simulations in the pipeline (HSC70, VAX 8200, VAXstation 2000, VAXstation 3100...). Hopefully I'll get these released soon too. Matt _______________________________________________ Simh mailing list [email protected] http://mailman.trailing-edge.com/mailman/listinfo/simh