From: "Barman, Sibon B \(Sibon\)" <[EMAIL PROTECTED]>

   Is changing codec sequence in the 200 OK from 183 legal? I am guessing
   it is --- just need to verify if that's the case.

I doubt that it is OK.  In any one transaction, the SDP sent by one
agent must always be the same.  So you can't change the codec sequence
without changing the SDP.