The answer is Yes. 
The dialog is established at both UA(s) and anyone can send a BYE. 

Please refer to section 3.1.2 
http://www.ietf.org/internet-drafts/draft-ietf-sipping-race-examples-01.
txt

- Nasir





Date: Wed, 30 May 2007 21:13:55 +0530
From: "P Raj" <[EMAIL PROTECTED]>
Subject: [Sip-implementors] BYE after CANCEL & 200 OK
To: sip-implementors@cs.columbia.edu
Message-ID:
        <[EMAIL PROTECTED]>
Content-Type: text/plain; charset=ISO-8859-1; format=flowed

Hi

I just wanted to know, if BYE can be sent after 200 OK for a Cancel is
sent
at UAC.

Please see the below sequence & let me know.
Could you also let me know which section of RFC throws light on this.

Thanks & Regards
Prashanth

>  Message Sent
<  Message Received

UA1

 > INVITE

 < 100 Trying

< 180 Ringing

> CANCEL

< 200 OK for CANCEL

< 200 OK for INVITE

> ACK

*> BYE*


UA2

> INVITE

< 100

< 180 Ringing

< 200 OK

> CANCEL

> ACK for 200 OK INVITE

> BYE

< 200 OK


------------------------------

_______________________________________________
Sip-implementors mailing list
Sip-implementors@cs.columbia.edu
https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors


End of Sip-implementors Digest, Vol 50, Issue 58
************************************************

Notice:  This email message, together with any attachments, may contain 
information  of  BEA Systems,  Inc.,  its subsidiaries  and  affiliated 
entities,  that may be confidential,  proprietary,  copyrighted  and/or legally 
privileged, and is intended solely for the use of the individual or entity 
named in this message. If you are not the intended recipient, and have received 
this message in error, please immediately return this by email and then delete 
it.
_______________________________________________
Sip-implementors mailing list
Sip-implementors@cs.columbia.edu
https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors

Reply via email to