> I am trying to create an OUT OF DIALOG BYE. > > Logically, one of the options would be to change the from or > to tags. Just wanted to know if I send a BYE without 'to' > tag, will it be an out-of-dialog bye?
Per rfc3261, yes. Per obsoleted rfc2543, maybe; it depends upon if tags were used during call setup. > What are the other ways of simulating an out-of-dialog bye? You have listed them all unless you want to test dialog usage concepts per http://tools.ietf.org/id/draft-ietf-sipping-dialogusage-06.txt and send a BYE over subscription created dialog (or one no longer containing INVITE usage). Incase your questions are not related to compliance testing, rfc3261 section 15 indicates "A UA MUST NOT send a BYE outside of a dialog." _______________________________________________ Sip-implementors mailing list [email protected] https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors