Hi All,
I have a doubt regarding continuous transmitting of provisional
response. In our system we are having two SIP entities
Assume one sip entity is softx and other is SCP.
SCP sends 180 with SDP to softx to have early dialog and we are having a
situation that early dialog should go for 4 minutes.
After 2 minutes and 30 seconds SCP is retransmitting the 180 with SDP again
but the softx is not accepting the same because it has already send PRACK
for the earlier response and it is releasing the call after 3 minutes
because it did not get any new response.
Can any one say whose behavior is correct? (I checked with RFC3262 I think
SCP behavior is correct)
Thanks in advance.
Thanks and Regards,
Ganesh
_______________________________________________
Sip-implementors mailing list
[email protected]
https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors