Yes, Notify alone is enough to establish dialog in UAC.

-Rockson 

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
dushyant
Sent: Wednesday, September 17, 2008 3:53 PM
To: [email protected]
Subject: [Sip-implementors] Query related to Subscribe - Notify dialog

Hi All,

 

I have a query related to Subscribe - Notify dialog.

 

RFC 3265 says - 

3.3.4. Dialog creation and termination

If an initial SUBSCRIBE request is not sent on a pre-existing dialog,
the subscriber will wait for a response to the SUBSCRIBE request or a
matching NOTIFY.

 

Does that mean once UAC receives Notify for a dialog, 2xx-6xx response
is not required for completion of the dialog?

 

Consider a scenario, 

 

1. UAC sends SUBSCRIBE

2. UAS send 200 OK but this gets lost in the network.

3. UAS creates the dialog on its side.

4. UAS sends NOTIFY, UAC receives the same.

 

My question is should UAC wait for 2xx? If yes, what should be the
behavior of UAC on timeout? If the behavior of UAC is to terminate the
dialog, should it send a SUBSCRIBE (with expires = 0) to end the dialog?

 

Dushyant P S Dhalia

 

_______________________________________________
Sip-implementors mailing list
[email protected]
https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors

_______________________________________________
Sip-implementors mailing list
[email protected]
https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors

Reply via email to