The same section says that complete To and From fields including any tags are stored as remote and local address. Subsequent requests in dialog should set their To and From headers to remote and local addresses, which are complete To and From headers. This is done to be compatible with RFC 2543, where request would only match the dialog if complete To, From and Call-ID match.
____________________________ Roman Shpount www.telurix.com On Fri, Feb 19, 2010 at 3:22 PM, Paul Kyzivat <[email protected]> wrote: > > > Roman Shpount wrote: > >> From/To header should be preserved completely with all of its parameters >> to be compatible with RFC 2543. RFC 3261 Section 11.2 Callee Issues Response >> says that "The response MUST copy the To, From, Call-ID, CSeq and Via fields >> from the request." This implies that complete header, including all the >> header parameters are copied. The RFC 3261 should still match the request >> based on To and From tags. Older, RFC 2543 based user agents, will only >> match request to dialog if complete To and From headers are preserved. >> > > That is pertinent to the *response* to the request. > > The question is about subsequent requests within the dialog. > > Thanks, > Paul > _______________________________________________ Sip-implementors mailing list [email protected] https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors