2010/7/6 goutam kumar <[email protected]>:
> Hi,

Hi, please set always a descriptive subject in every mail.


> During implementation I have come across two situations,
>
> 1) If for an incoming call, the callee dosen't receive an ACK for a 200 OK,
> should the call fail??

The callee should then generate a BYE.


> 2) In an outgoing call, if the end-user hangs-up a call, i.e. goes ON_HOOK
> while the remote party has still not answered the call, should the local SIP
> UA send a CANCEL message to the callee???

Yes. But it could also send an *in-dialog* BYE to terminate just a
pending branch (in case of forking).



-- 
Iñaki Baz Castillo