Hi I receive a re-INVITE for a switchover from G.711 to T.38 with the following SDP:
v=0 o=ABC 1542876549 1542876550 IN IP4 W.X.Y.Z s=abs c=IN IP4 A.B.C.D t=0 0 m=image 32603 udptl t38 a=T38FaxVersion:0 a=T38MaxBitRate:9600 a=T38FaxRateManagement:transferredTCF a=T38FaxMaxBuffer:256 a=T38FaxMaxDatagram:256 a=T38FaxUdpEC:t38UDPRedundancy m=image 0 UDPTL t38 a=sendrecv a=T38FaxVersion:0 a=T38FaxRateManagement:transferredTCF a=T38FaxMaxBuffer:0 a=T38FaxMaxDatagram:512 a=T38MaxBitRate:14400 a=T38FaxUdpEC:t38UDPRedundancy Is this allowed by the standards? And if so, are the attributes for the second/muted m line relevant, considering that the port was set to zero? Thank you Fred -- GMX DSL SOMMER-SPECIAL: Surf & Phone Flat 16.000 für nur 19,99 €/mtl.!* http://portal.gmx.net/de/go/dsl _______________________________________________ Sip-implementors mailing list [email protected] https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors