Hello Una,

 

It seems you have to synchronize both sides of your scenario using <pause>. 
Could you show us your uac scenario ?

You also may use -rtp_echo on the uas side if you just want to have a RTP 
stream in both directions.

 

Regards,

 

Olivier Boulkroune

 

________________________________

De : [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] De la part de [EMAIL PROTECTED]
Envoyé : jeudi 14 juin 2007 10:57
À : [email protected]
Objet : [Sipp-users] can I use exec pcap play in the server as well as 
theclient?

 

Hi

 

I want to create 10 calls with voice in both directions. I can successfully run 
exec pcap from the client (as in the standard example) but I cannot get it to 
work in the reverse direction.

 

To do this I inserted an exec pcap in the uas between the receive for the ACK 
and the BYE.


  <recv request="ACK"
        optional="true"
        rtd="true"
        crlf="true">
  </recv>

 

 

<nop>
  <action>
    <exec play_pcap_audio="pcap/g711a.pcap"/>
  </action>
</nop>

 

  <recv request="BYE">
  </recv>

 

However, when I run it I get 


2007-06-14 08:13:25: Aborting call on an unexpected BYE for call: 1-14466@

for each of the 10 calls 

 

 

 

Is it even possible to run the exec pcap from the server?

 

Thanks

 

Una

 

 

 

 Una Ramsay

 

 Intelligence Support Systems
Agilent Technologies

<http://m/brand/ISS_Email_Signature.gif>  

 

 

-------------------------------------------------------------------------
This SF.net email is sponsored by DB2 Express
Download DB2 Express C - the FREE version of DB2 express and take
control of your XML. No limits. Just data. Click to get it now.
http://sourceforge.net/powerbar/db2/
_______________________________________________
Sipp-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/sipp-users

Reply via email to