By default, SIPp is closed loop and will not allow more than 3 * call 
duration (with a minimum of one second) calls to be outstanding.

Specify -l 0 to get open loop behavior, which removes this limit.

Charles




Evgeny Miloslavsky <[email protected]> 
01/21/2009 04:46 AM

To
<[email protected]>
cc

Subject
[Sipp-users] Calls limit






Hi
While trying to create traffic of 30 REGISTER/sec during 5 seconds (that 
is 150 REGISTERS totally), I saw that only 90 REGISTERs are created and 
there is a following output at scenario screen:
  90 calls (limit 90)
What is this limit? Is this value changeable? And if it does how do I 
change it.
 
Regards,
Evgeny Miloslavsky
Systest Engineer
Juniper Networks Solutions Israel LTD.