> From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] On Behalf Of > Laurentiu Ceausescu > Sent: Wednesday, September 10, 2008 10:07 AM > To: [EMAIL PROTECTED] > Subject: [sipX-dev] XCF-2692 questions > > Hi, > > Regarding XCF-2692 > (http://track.sipfoundry.org/browse/XCF-2692) I need some > clarification: > 1. In global configuration section for alarm server what is > the maximum number of e-mail addresses? For that I think > alarm.xsd must be modified.
There is no maximum. Well, that's kind of dangerous to say, isn't it! Scott wanted a maximum of one, but Al wanted more. We could pick a number like 5... > 2. For individual alarms configuration is required to add a > new alarm from UI or only manually editing corresponding > files (pack-config.xml and pack-strings.xml)? > In the first case, the unique id of an alarm will must be > provided by administrator. It's not clear for me what happens > for multiple "packs" > of alarms. Admins cannot change alarm codes, or add alarms, if that is what you mean. The only thing that can be controlled per-alarm is what notifications to generate. Carolyn _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev