Looking at this issue I wanted to get some opinions on expected behavior for sipXbridge. (this is coming from XECS-1692)
If a customer has ISDN (BRI/PRI) and sipXbridge trunks from an ITSP I can see this causing quite a few problems. If your primary DID is out the ISDN and your CLID is set for your user account the sipXbridge will not work for you? Does everyone see this as a configuration error? Regards, Al