Hi all,

I would like to summarize what we discussed with Kevin and Scott about 
the configuration stamp for sipx services ( 
http://track.sipfoundry.org/browse/XCF-2612 ).
SipXsupervisor needs the configuration stamp value in order to compare 
it to the actual service version. If they are both the same, the service 
can be started. Otherwise the state of the service will be set to 
"ConfigurationVersionMismatch".
SipXconfig should be responsible for sending the configuration stamp 
value via XML-RPC layer to SipXsupervisor. This should happen whenever 
the configuration for a specific service changes (and gets replicated) 
or when a new service is added for a specific host. As far as we now, 
the configuration of a service can get changed at application's startup 
or from the System/Server/Services page (as per user action).
In conclusion the stamp will be passed to sipXsupervisor in the above 
use cases.

Is this information correct and complete ? Will this work in a 
distributed environment ?
Please share your opinion on this matter.

Thanks,
Bogdan