On Thu, 2008-09-25 at 07:20 -0700, Dutkiewicz, Marek wrote: > There was an additional field added to the BLF signaling in SIP 3.1. > This parameter is the 'direction' attribute specified in RFC4235. It is > used to differentiate between and outgoing and incoming call to a phone; > both of which have a BLF state of 'proceeding'. The phone will only > 'blink the LED' for proceeding calls which have a direction="recipient"
(Actually, the BLF state is 'early'.) > For more details I recommend that you take a capture of the BLF > signaling for a phone dialing out and receiving a call whilst being > monitored. > > I'll leave it to others more knowledgeable than me to assess whether > this will impact the sipXecs BLF implementation. The additional information should be passed through by the RLS without any change in the sipX code. Dale _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev