On Thu, 2008-09-25 at 07:20 -0700, Dutkiewicz, Marek wrote:
> There was an additional field added to the BLF signaling in SIP 3.1.
> This parameter is the 'direction' attribute specified in RFC4235. It is
> used to differentiate between and outgoing and incoming call to a phone;
> both of which have a BLF state of 'proceeding'. The phone will only
> 'blink the LED' for proceeding calls which have a direction="recipient"

(Actually, the BLF state is 'early'.)

> For more details I recommend that you take a capture of the BLF
> signaling for a phone dialing out and receiving a call whilst being
> monitored.
> 
> I'll leave it to others more knowledgeable than me to assess whether
> this will impact the sipXecs BLF implementation.

The additional information should be passed through by the RLS without
any change in the sipX code.

Dale