I've been looking at XECS-1778 which deals with the Call Resolver Agent
(used in HA setups) leaving a number of stunnel processes running after
shutdown.  This issue appears to occur only if the shutdown is done via
Supervisor as opposed to using the shell script for the Call Resolver
Agent directly from a command line.
On startup of the Call Resolver Agent 6 stunnel processes are created (1
parent and 5 children).  When the shutdown occurs via Supervisor, the
parent process is killed but all 5 children remain.
There appeared to be no reason why the children weren't killed so I
started investigating stunnel and found out that others have been having
this issue with version 4.24 which coincidentally is the version we're
using.  The issue may have been fixed in version 4.26 but I can't find
this version available on FC 8 which is the OS I'm using.
What is the process for getting a newer version of stunnel included in
3.11 or is it even possible at this stage.

Thanks in advance
Raymond  