On Tue, 2008-12-09 at 15:19 -0500, Raymond Dans wrote:
> In doing my testing for XECS-1955 "Process dependencies on IMDB do not
> appear to be enforced by sipXsupervisor", I've run into some issues with
> processes requiring IMDB resources that do not seem to ever be
> generated.
>
> One of the tables that seems to be missing completely is the Hunt Group
> table. Does anyone know if this table is needed at all anymore? I
> never see it generated even though I have hunt group information (alias
> table seems to be used now).
The hunt group table was used by a redirector that implemented a
different hunt group scheme than we use now. The redirector sources
exist, but are never configured now (and that scheme is not supported by
sipXconfig).
I believe we can and should remove the implementation,
sipXregistry/lib/redirect_plugins/SipRedirectorHunt.{cpp,h}, the hunt
group database, and any references to it that we find.