The scenario is :

Sipxbridge sends an inbound call to the operator
Operator refers the call to extension 203.
Extension 201 tries to pick up the call.

If I dont redirect the call from the operator -- i.e. try to directly
send the call to 203 and then do the pick up when 203 is ringing, it
works fine. 201 is able to pick up the call.

However, if I redirect the call and then attempt to do the pickup it fails.

On Frame 113 of the attached trace notice that the registrar returns a
302 with a Contact: Unknown URL scheme.

Any ideas what might be happening here?

Note that the local case works fine.  So this is possibly something I
am doing wrong in SIPXBRIDGE


Thanks in advance for any help.

Ranga

-- 
M. Ranganathan

Attachment: sipxbridge-pickup.xml.gz
Description: GNU Zip compressed data

_______________________________________________
sipx-dev mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-dev
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev

Reply via email to