I'm in the beginning stages of testing a new server to understand native trunking with sipxbridge and remote worker setups.
My server has the role assigned. I've sent the sipxbridge profile to the system. I still see an issue (known) to restart several services and have made sure that is done before trying test calls and registrations. I've attached a rudimentary picture of my layout so I can document my way through this, and at some point provide a usable legnd for a setup since the process is a little more involved than setting up a gateway. I can register phones locally and via VPN, but not natively over the Internet. I can make calls into the system if they go to the operator, but have a problem with rfc2833 being recognized. *** A. Public IP Address for firewall. B. Private IP address for sipXecs C. port 5060 (tcp/upd) are forwarded from A > port 5080 on B. D. Ports 30000-31000 TCP/UDP are forwarded from A>B E. SERVER NAT is set to A. (specify IP) at port 5060. F. SIP trunk configured for account at bandwidth.com routed to sipXbridge sbc. G. SBC settings are PUBLIC=5060 EXTERNAL=5080 sipXecs is setup with DNS configured. PUBLIC DNS is maintained elsewhere and points to the records properly. *** My questions at this point are: Is my firewall setup properly? I realize the software has several UI changes in process, but I'm trying to understand the system before the release is out so I can decide whether or not to purchase an ingate after trying it before a change here at the end of April. I'd appreciate any review. _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev