On Mon, Mar 30, 2009 at 3:20 PM, Dale Worley <[email protected]> wrote:
> On Mon, 2009-03-30 at 10:25 -0400, Raymond Dans wrote:
>> The actual component has a version in its process xml file (under
>> /usr/share/sipxecs/process.d).
>> SipXconfig, I believe, gets a version number from its properties file
>> (sipxconfig.properties) and should call the XML/RPC SetConfigVersion
>> using its version number for each of the services it will ask to start.
>> Supervisor will then check the version that was set against what was
>> found in the process xml file.  If they don't match, you don't get
>> started.
>
> What do you do to get this error cleared out?


Send Profile to the HA server from sipxconfig. As discussed on #sipx,
I think we may want to rework it so that step is not necessary (
confused the daylights out of me ).


>
> Dale
>
>
>



-- 
M. Ranganathan