On Mon, Mar 30, 2009 at 3:20 PM, Dale Worley <[email protected]> wrote: > On Mon, 2009-03-30 at 10:25 -0400, Raymond Dans wrote: >> The actual component has a version in its process xml file (under >> /usr/share/sipxecs/process.d). >> SipXconfig, I believe, gets a version number from its properties file >> (sipxconfig.properties) and should call the XML/RPC SetConfigVersion >> using its version number for each of the services it will ask to start. >> Supervisor will then check the version that was set against what was >> found in the process xml file. If they don't match, you don't get >> started. > > What do you do to get this error cleared out?
Send Profile to the HA server from sipxconfig. As discussed on #sipx, I think we may want to rework it so that step is not necessary ( confused the daylights out of me ). > > Dale > > > -- M. Ranganathan _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev