On Wed, Nov 11, 2009 at 11:33 AM, Andy Spitzer <[email protected]> wrote:
> Woof!
>
> On Wed, 11 Nov 2009 08:24:28 -0500, M. Ranganathan <[email protected]> wrote:
>
>> I seem to recall some issues with
>> FreeSwitch in this context so I thought it would be wise to inquire.
>
> FreeSWITCH's config has been changed to accept 3PCC call flows.
>
> --Woof!
>

I sent polycom the following SDP :

v=0
o=- 5022363611140259718 1 IN IP4 192.168.5.75
s=SipXconfig
c=IN IP4 192.168.5.75
t=0 0
a=sendrecv

(Note : no m= line as stipulated by RFC 3725 flow 4 arc 1 )

It replied Not Acceptable Here .

Any ideas as to why this might be the case?

I can send it an INVITE with NO sdp in step 1 but that is not what the
RFC says I ought to do in step 1. It specifically states that the m=
line be removed from the SDP.

Ranga

-- 