Recently I took a system running 3.10 on FC6, backed it up, built a new 3.10.2 system on Centos 5, did a restore and upgraded it to 3.10.3.
Everything went well, except I found it necessary to reissue certificates. There are no errors, everything registers, everything works except this: I have a time based AA, it play one greeting after hours, another during normal working hours. I've removed the AA and recreated it, and I've activated the dialplan. The AA feature is set to use the AA in the dialplan. The dialplan says use the afterhours as default. Use the Operator during working time. My working hours are 8:30am-5:30pm M-F, and the system time and timezone has no complaints. What I've noticed is the greeting that plays never changes with the time periods unless I manually change it at the AA Feature. The greeting is there, it has the proper name and I can play it and change it to play the greeting from the AA, but it just won't work according to the dialplan. I've deleted and recreated the AA dialplan entry and it stll does not work. The only way I got it to work was to create two new AA's and let the dialplan use them, but the default ones don;t seem to behave the way I think they should and I can't delete the default ones. Does anyone have an idea of where to look at this to determine why this happened? Thanks, Tony