On Thu, 2009-02-12 at 09:43 -0600, Mitchell, Kenny (Ineos) wrote: > Part of my problem appears to be related to registering the gateway with > SipX. The gateway has various options for registering by endpoint or by > gateway, but what do I actually set up on the SipX config to get it to > register? Do I need to set anything? A fake extension with a username > and password for each port? One for the gateway as a whole? My calls > out are hitting the gateway (I can see the call count incrementing in > the log) but it is logged under the 'failed due to no routing' section.
I may be out of date, but the scheme that has worked in the past is this: First, consider the extension numbers (SIP "user part") that the gateway will be accepting calls for. (I expect that there is one extension number per port on the FXO, but it's possible you could configure them to be ganged or trunked, so calls to a single extension number could go out any of the ports, as if the FXO was simulating a multi-line phone.) Configure each of these users on sipX, with a password. Configure the gateway to submit registrations for each of these users, paired with the appropriate FXO ports. Then calls to the extensions should be routed to the FXO gateway, which should accept them and route them out the appropriate ports. Dale _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users