Hi everybody,
After configuring my Patton Smartonode gateways with the following ACL,
call pickups of PSTN originated calls don't work anymore. I've
experienced also some RTP problems.
Here's the acl:
...
profile acl SIP-IN
permit 1 ip host 192.168.1.1 any
permit 2 ip host 192.168.1.2 any
deny 3 tcp any any eq 5060
deny 4 udp any any eq 5060
permit 5 ip any any
context ip router
interface LAN
ipaddress 192.168.1.3 255.255.255.0
use profile acl SIP-IN in
tcp adjust-mss rx mtu
tcp adjust-mss tx mtu
...
Can you explain me why?
Thanks,
Max
--
Massimo Vignone
UniMORE - Servizi Informatici - Reti e Sistemi
Phone: +39.059.2058032 Fax: +39.059.2058034
sip:[email protected] ISN:8032*881
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users