1. Configure the Grandstream FXO.

 

Advanced settings:

DTMF Payload Type: 101

 

FXO Lines

4. Wait for Dial-Tone(Y/N):ch1-8:Y;

5. Stage Method(1/2):1

6. Min Delay Before Dial PSTN: 500

 

7. Unconditional Call Forward to VOIP: 

This parameter redirects incomming calls to the voip extension. You can assign 
one to one or just redirect to the autoanswer system.

              User ID         SIP server     SIP Destination

Example: ch1-8:100;     ch1-8:p1      ch1-8:5060

This sets that incoming calls from FXO lines 1 to 8 are redirected to extension 
100 in the sip server specified in p1 (Profile1) to port 5060

sip:[email protected]:5060

 

You can do DID here, configuring each FXO line to a voip extension

ch1:101;ch2:102;etc or try using ch1-8:101+

 

 PSTN to VOIP Caller ID Setting 

1. Caller ID Scheme:ch1-8:4;

2. Caller ID Transport Type:ch1-8:1;

 

Channels

Call Progress Tones adjust this settings to your country you can find them 
here: http://www.3amsystems.com/wireline/tone-search.htm

 

Channel Specific Setting 

1. DTMF Methods(1-7):ch1-8:2;

 

Dial Plan

Leave as default {x+}

 

Profile 1

Activate Profile: Yes

Profile Name: SIPXECS

SIP Server: yoursipx.domainame or ip address

Outbound Proxy: yoursipx.domainame or ip address

 

Note: If you use domain names, remember to modify your DNS records to allow 
discovery of the server and sip transport. You can use the DNS wizard in the 
sipx webui.

 

Use DNS SRV: Yes (if you have setup the DNS advisor settings)

User ID is phone number: No

SIP Registration: No

Early Dial: No

Force INVITE: Yes

Enable 100rel: Yes

Refer-To Uses Target Contact: Yes

 

2. Configure SIPX

Add an unmanaged gateway, just complete the Address with the ip address of the 
gateway.

 

Modify the Dial plan to use this gateway.

 

 

IMPORTANT: There is a bug in the Grandstream FXO gateway if you use transformed 
numbers in dial rules, you allways get dialed the original number this issue 
has been reported to Grandstream but, there is still no notice of a fix. 
Example: user dials 944444444, you strip the 9 and the resulting number is 
44444444, but the gateway will dial the original one (944444444).

 

I hope this helps you,








 

 





P Antes de imprimir este correo, preguntate si realmente es necesario
 


 



From: [email protected]
To: [email protected]; [email protected]
Date: Mon, 15 Jun 2009 08:22:43 +0000
Subject: Re: [sipx-users] Grandstream GXW-410x FXO Gateway



I've successfully made Grandstream GXW4108 FXO Gateway work with SIPX. The 
important thing is to setup the correct dial plan of GXW4108. 
 


Date: Fri, 12 Jun 2009 14:43:56 -0400
From: [email protected]
To: [email protected]
Subject: [sipx-users] Grandstream GXW-410x FXO Gateway





Anyone have a Grandstream GXW-410x FXO Gateway working with sipXecs?  If so 
would you mind sharing your configuration of both the gateway and your sipXecs 
gateway settings?
 
Gary


更多热辣资讯尽在新版MSN首页! 立刻访问!
_________________________________________________________________
Descubre todas las formas en que puedes estar en contacto con amigos y 
familiares.
http://www.microsoft.com/windows/windowslive/default.aspx
_______________________________________________
sipx-users mailing list [email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to