My topology is...
WAN ========= cicso pix 501 firewall =========== DMZ (subnet)======== Microsoft ISA 2006 firewall/proxy =========== Internal Network DMZ network spans 2 subnets. They are 192.168.4 and 192.168.5. The sipx server's address is 192.168.4.25. I have successfully configured bridging and remote worker processes. Meaning, 1) from wan, I am able to register and make phone calls 2) from 192.168.4 subnet, I am able to register and make phone calls. However, though I could register from 192.168.5 and internal networks, I can not here audio (I think it is one way) when making phone calls. What provisions would I have to make to be able to place successful phne calls from 192.168.4 subnet. Thanks in advance _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users sipXecs IP PBX -- http://www.sipfoundry.org/