Set the phone to provision via ftp.
Set your firewall to forward port 21 to sipx. Re-provision the phone (manual
reboot is required because line1 is not registered). Once done, you can
close port 21 on your firewall if you wish.
============================
Tony Graziano, Manager
Telephone: 434.984.8430
Fax: 434.984.8431

Email: [email protected]

LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
Fax: 434.984.8427

Helpdesk Contract Customers:
http://www.myitdepartment.net/gethelp/

----- Original Message -----
From: [email protected]
<[email protected]>
To: sipX Users Mailing List <[email protected]>
Sent: Fri Jan 08 13:18:49 2010
Subject: [sipx-users] Remote Worker Configuration for SoundPoint 320

I have a SoundPoint 320 that I have set up as a remote worker phone. I
initially did all of the configuration through sipXecs and pushed it to the
phone. I was then able to use the phone offsite.

Something has since happened and the phone is no longer able to connect to
sipXecs on Line 1, but can connect to an ITSP on Line 2. I am trying to
verify all of the settings. Everything looks good, except I can't seem to
find the Outbound Proxy for Line 1 through the SoundPoint web interface. I
can only find the Outbound Proxy under SIP | Servers, which I think would
affect all lines (I don't want to set the Outbound Proxy for Line 2).

Does anyone know if it's possible to set the Outbound Proxy for a specific
line through the SoundPoint web interface? If not, what are my options? This
phone is now in a different country, so I cannot provision it locally. Is
there any way to provision remote worker phones?