On Tue, Jan 26, 2010 at 12:41 PM, Hiral Patel <[email protected]> wrote:
> My SipXecs PBX is connected an unauthenticated sip trunk for which I need to
> enable SipXecs bridge to be able to work around the lack of REFER support on
> the sip trunk.
>
>
>
> The sip trunk sends to sipX on port 5060 therefore any incoming dialogue
> bypasses sipXbridge and hence outgoing signalling also are bypassing
> sipXbridge for the same dialogue.
>
>
>
> What I would like to know is if it is possible to re-configure sipX so that
> sipXbridge listens on 5060 and sipX listens on 5080?



No you should not configure it this way. You should configure it as follows:

1. Allow sipx proxy server to continue to listen on port 5060.
2. Allow sipxbridge to continue to listen on port 5080 ( both of these
are defaults ).

3. Set the public port in the sipxbridge configuration page to port
5060. See 
http://sipx-wiki.calivia.com/index.php/SIP_Trunking_with_sipXecs:_Overview_and_Configuration#2._Configure_SipXbridge

4. Map your NAT to send WAN packets arriving at 5060 to port 5080 on
the host where sipxbridge  is configured and vice versa.


Ranga



>
>
>
> I understand there is a way to map external 5060 to internal 5080, but I am
> not sure how to do this, can anyone help?
>
>
>
> Also, if the above is possible does it have any implications e.g. Ranga
> mentioned that remote worker maybe effected?
>
>
>
> Regards,
>
>
>
> Hiral Patel,
>
> OnRelay
>
>
>
> _______________________________________________
> sipx-users mailing list [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users
> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
> sipXecs IP PBX -- http://www.sipfoundry.org/
>



-- 
M. Ranganathan
_______________________________________________
sipx-users mailing list [email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to