On Tue, Jan 26, 2010 at 12:41 PM, Hiral Patel <[email protected]> wrote: > My SipXecs PBX is connected an unauthenticated sip trunk for which I need to > enable SipXecs bridge to be able to work around the lack of REFER support on > the sip trunk. > > > > The sip trunk sends to sipX on port 5060 therefore any incoming dialogue > bypasses sipXbridge and hence outgoing signalling also are bypassing > sipXbridge for the same dialogue. > > > > What I would like to know is if it is possible to re-configure sipX so that > sipXbridge listens on 5060 and sipX listens on 5080?
No you should not configure it this way. You should configure it as follows: 1. Allow sipx proxy server to continue to listen on port 5060. 2. Allow sipxbridge to continue to listen on port 5080 ( both of these are defaults ). 3. Set the public port in the sipxbridge configuration page to port 5060. See http://sipx-wiki.calivia.com/index.php/SIP_Trunking_with_sipXecs:_Overview_and_Configuration#2._Configure_SipXbridge 4. Map your NAT to send WAN packets arriving at 5060 to port 5080 on the host where sipxbridge is configured and vice versa. Ranga > > > > I understand there is a way to map external 5060 to internal 5080, but I am > not sure how to do this, can anyone help? > > > > Also, if the above is possible does it have any implications e.g. Ranga > mentioned that remote worker maybe effected? > > > > Regards, > > > > Hiral Patel, > > OnRelay > > > > _______________________________________________ > sipx-users mailing list [email protected] > List Archive: http://list.sipfoundry.org/archive/sipx-users > Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users > sipXecs IP PBX -- http://www.sipfoundry.org/ > -- M. Ranganathan _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users sipXecs IP PBX -- http://www.sipfoundry.org/